Toshiba Haori Design (Nordic) 25
Toshiba Haori Design (Nordic) 25
Energy class: A+++
Regular price
€1.977,00 EUR
Regular price
Sale price
€1.977,00 EUR
Unit price
per
The new fabric-upholstered air source heat pump Toshiba Haori DESIGN 25 has been awarded the iF Design Award
The new Toshiba Air heat pump Toshiba Haori DESIGN has been awarded the iF Design Award in the building technology category 2021. The air heat pump Toshiba Haori DESIGN is covered with an upholstery fabric that can be changed to match the interior of your home.
Product information
Product description
Technical information
Lämmitysteho | | 3,2 kW |
---|---|---|
Lämmitystehon alue (min. - max.) | | (1.0 - 7.2) kW |
Ottoteho (min. - nim. - max.) | H | (0.2 - 0.65 - 2.4) kW |
Pdesignh | | 2.7 kW |
COP | | 4.92 W/W |
SCOP | | 5.1 |
Energialuokka | H | A+++ |
Maksimi lämmitysteho -10°C | H | 4.1 kW |
Maksimi lämmitysteho -15°C | H | 3.8 kW |
Maksimi lämmitysteho -20°C | H | 3.2 kW |
Maksimi lämmitysteho -25°C | H | 2.6 kW |
Jäähdytysteho | | 2.8 kW |
Jäähdytysteho (min. - max.) | | (1.1 - 3.5) kW |
Ottoteho (min. - nim. - max.) | C | (0.22 - 0.63 - 0.87) kW |
Pdesignc | | 2.8 kW |
EER | | 4.44 W/W |
SEER | | 7,7 |
Energialuokka | C | A++ |
Fyysiset mitat / sisäyksikkö | | RAS-25N4KVRG-ND |
Ilmavirta (k) | C | 690 - 192 m3/h - l/s |
Ilmavirta (m) | C | 330 - 92 m3/h - l/s |
Äänen painetaso (k/m (q)) | C | 42/19 dB(A) |
Äänentehotaso (k) dB(A) | C | 55 dB(A) |
Ilmavirta (k) | H | 820 - 278 m3/h - l/s |
Ilmavirta (m) | H | 330 - 92 m3/h - l/s |
Äänen painetaso (k/m (q)) | H | 45/19 dB(A) |
Äänen tehotaso (k) | H | 58 dB(A) |
Mitat läppä kiinni (KxLxS) | | 300x987x210 mm |
Mitat läppä auki (KxLxS) | | 355x987x210 mm |
Paino kg | | 11 kg |
Fyysiset mitat / ulkoyksikkö | | RAS-25J2AVSG-ND1 |
Ilmavirta (max) | C | 1920 - 532 m3/h - l/s |
Äänen painetaso (yötoiminto) | C | 46 (39) dB(A) |
Äänen tehotaso | C | 59 dB(A) |
Toiminta-alue | C | -15~46 °C |
Ilmavirta (max) | H | 1920 - 532 m3/h - l/s |
Äänen painetaso (yötoiminto) | H | 48 (41) dB(A) |
Äänen tehotaso (h) | H | 61 dB(A) |
Toiminta-alue | H | -30~24 °C |
Mitat (kxlxs) | | 550x780x290 mm |
Paino | | 38 kg |
Kompressorityyppi | | DC Twin Rotary |
Putkikoot (kaasu-neste) | | 3/8” - 1/4” |
Minimi putkipituus | | 2 m |
Maksimi putkipituus | | 20 m |
Maksimi korkeusero | | 12 m |
Putkipituus ilman lisätäyttöä | | 15 m |
Kylmäainetäytös | | 0,76 kg |
Virransyöttö | | 220 - 240 V - 1 ph - 50 Hz |
Installation
Contents of the basic installation
- Refrigerant pipes between indoor and outdoor unit (maximum 4 meters, additional meters are paid directly to the installer)
- Cover gutters and a maximum of 4 meters of condensate hose
- Installation of the indoor unit up to a height of 2.5 meters
- Outdoor unit wall bracket and vibration dampers, up to a height of 2 meters
- Pass-through (excl. wall requiring diamond drilling for an additional fee)
- Sealing/massing of wall penetrations
- Pulling electricity up to 5 meters from the electricity supply point.
- Superficial cleaning, does not include removal of packaging material
- Start-up and testing of the air heat pump
- Instructions for use for the customer
Work outside the basic installation for an additional fee (paid directly to the installer)
- Longer piping, longer cover gutter and longer condensate control
- Electrical connections (arranged separately)
- Installing the indoor unit higher than 2.5 m
- Use of a crane (to be arranged separately, depending on the area and rental service provider)
- Diamond drilling – concrete, stone and brick walls that require diamond drilling (to be arranged separately)
- Installation of the archipelago must be agreed separately!
Important information before installation
- If before installing the heat pump you have to do demolition work (e.g. if you have to remove the old pump and it is somehow built in), then this is not included in the price of the basic installation. This must either be agreed separately with the installer or the work must be completed by yourself before installing the heat pump.
- The places where the indoor and outdoor units are installed must be accessible and ready for the units to be installed. If the outdoor unit is installed on a ground stand, the ground beneath it must be ready for installation (concrete/stone slabs or other hard and flat surface).
- The customer is responsible for the current strength of the existing electrical network. If there is a need for it, the customer himself must agree on the suitability of the installation of the device with the owner of the house/housing corporation or the municipal administration.
- Any electrical work is not included in the basic installation price. If the heat pump installer cannot do the electrical work himself, they must be ordered from another company before installing the heat pump. This will be agreed with the installer before installing the heat pump.
Contact our expert
Call or send a message - we'll get back to you soon (weekdays from 8 a.m. to 8 p.m.). You can also get a free mapping visit from us.
-
Tel. 09 231 000 78
-
WhatsApp +044 209 1001
-
Email: info@lampopumpokotiin.fi